{"product_id":"endothermic-atmosphere-generator","title":"ENDOTHERMIC ATMOSPHERE GENERATOR","description":"\u003cp data-start=\"25\" data-end=\"403\"\u003e\u003cstrong data-start=\"25\" data-end=\"41\"\u003eDescription:\u003c\/strong\u003e\u003cbr data-start=\"41\" data-end=\"44\"\u003eSECO\/WARWICK endothermic atmosphere generator, Type G-60-ET. Designed to produce a controlled endothermic atmosphere from natural gas or propane and air. The dew point of the generated atmosphere is within the range of 0°C ± 5°C. Device was never used due to canceled customer orders. Upgrade to automatic gas flow regulation is possible through SECO\/WARWICK.\u003c\/p\u003e\n\u003cp data-start=\"405\" data-end=\"678\"\u003e\u003cstrong data-start=\"405\" data-end=\"435\"\u003eKey Components \u0026amp; Features:\u003c\/strong\u003e\u003cbr data-start=\"435\" data-end=\"438\"\u003eEndothermic atmosphere generator.\u003cbr data-start=\"471\" data-end=\"474\"\u003eVersion without automatic gas flow regulation.\u003cbr data-start=\"520\" data-end=\"523\"\u003eCatalyst: 5–8% Ni, 30 dm3.\u003cbr data-start=\"549\" data-end=\"552\"\u003eDesigned for methane or propane process gas.\u003cbr data-start=\"596\" data-end=\"599\"\u003eTechnical assessment, relocation, and installation within the EU are available.\u003c\/p\u003e\n\u003cp data-start=\"680\" data-end=\"754\"\u003e\u003cstrong data-start=\"680\" data-end=\"697\"\u003eManufacturer:\u003c\/strong\u003e SECO\/WARWICK\u003cbr data-start=\"710\" data-end=\"713\"\u003e\u003cstrong data-start=\"713\" data-end=\"727\"\u003eModel No.:\u003c\/strong\u003e G-60-ET\u003cbr data-start=\"735\" data-end=\"738\"\u003e\u003cstrong data-start=\"738\" data-end=\"747\"\u003eYear:\u003c\/strong\u003e 2013\u003cbr\u003e\u003cstrong data-start=\"910\" data-end=\"919\"\u003eLocation:\u003c\/strong\u003e Świebodzin, Poland\u003cbr\u003e\u003c\/p\u003e\n\u003cp data-start=\"756\" data-end=\"837\"\u003e\u003cstrong data-start=\"756\" data-end=\"778\"\u003eCapacity \/ Output:\u003c\/strong\u003e\u003cbr data-start=\"778\" data-end=\"781\"\u003eENDO atmosphere output: 60 m3\/h\u003cbr data-start=\"812\" data-end=\"815\"\u003eDew point: 0°C ± 5°C\u003c\/p\u003e\n\u003cp data-start=\"839\" data-end=\"872\"\u003e\u003cstrong data-start=\"839\" data-end=\"863\"\u003eMaximum Temperature:\u003c\/strong\u003e 1050°C\u003c\/p\u003e\n\u003cp data-start=\"874\" data-end=\"1004\"\u003e\u003cstrong data-start=\"874\" data-end=\"897\"\u003ePower Requirements:\u003c\/strong\u003e\u003cbr data-start=\"897\" data-end=\"900\"\u003eInstalled power: approx. 32 kW\u003cbr data-start=\"930\" data-end=\"933\"\u003eHeating element supply: 30 kW\u003cbr data-start=\"962\" data-end=\"965\"\u003e3 × 400 V \/ 50 Hz (3 × 380 V \/ 50 Hz)\u003c\/p\u003e\n\u003cp data-start=\"1006\" data-end=\"1224\"\u003e\u003cstrong data-start=\"1006\" data-end=\"1023\"\u003eProcess Data:\u003c\/strong\u003e\u003cbr data-start=\"1023\" data-end=\"1026\"\u003eProcess gas requirement:\u003cbr data-start=\"1050\" data-end=\"1053\"\u003eMethane: 13.6 Nm3\/h\u003cbr data-start=\"1072\" data-end=\"1075\"\u003ePropane: 5 Nm3\/h\u003cbr data-start=\"1091\" data-end=\"1094\"\u003eCalorific value of process gas:\u003cbr data-start=\"1125\" data-end=\"1128\"\u003eMethane: 35 MJ\/m3\u003cbr data-start=\"1145\" data-end=\"1148\"\u003ePropane: 93 MJ\/m3\u003cbr data-start=\"1165\" data-end=\"1168\"\u003eAir-gas ratio:\u003cbr data-start=\"1182\" data-end=\"1185\" data-is-only-node=\"\"\u003ePropane: 7.5 to 1\u003cbr data-start=\"1202\" data-end=\"1205\"\u003eMethane: 3.5 to 1\u003c\/p\u003e\n\u003cp data-start=\"1226\" data-end=\"1633\"\u003e\u003cstrong data-start=\"1226\" data-end=\"1240\"\u003eUtilities:\u003c\/strong\u003e\u003cbr data-start=\"1240\" data-end=\"1243\"\u003eCooling water supply: G1\/2\", 2–5 bar, 1.2 m3\/h, water temp. \u0026lt;25°C, hardness ≤10°n\u003cbr data-start=\"1324\" data-end=\"1327\"\u003eProcess gas supply: G3\/4\", 150–400 mbar\u003cbr data-start=\"1366\" data-end=\"1369\"\u003eCombustion atmosphere outlet: DN50 pipe, free outlet, max. 60 m3\/h\u003cbr data-start=\"1435\" data-end=\"1438\"\u003eSample extraction point: 30–80 mbar, connection with 6 mm inner diameter\u003cbr data-start=\"1510\" data-end=\"1513\"\u003eENDO atmosphere exhaust to furnace: G2\", 30–80 mbar, 60 m3\/h\u003cbr data-start=\"1573\" data-end=\"1576\"\u003eFlue gas extraction: approx. 1700 m3\/h at approx. 400°C\u003c\/p\u003e\n\u003cp data-start=\"1635\" data-end=\"1686\"\u003e\u003cstrong data-start=\"1635\" data-end=\"1655\"\u003eInstrumentation:\u003c\/strong\u003e\u003cbr data-start=\"1655\" data-end=\"1658\"\u003eTemperature sensor: Type S\u003c\/p\u003e\n\u003cp data-start=\"1688\" data-end=\"1719\"\u003e\u003cstrong data-start=\"1688\" data-end=\"1699\"\u003eWeight:\u003c\/strong\u003e\u003cbr data-start=\"1699\" data-end=\"1702\"\u003eApprox. 2600 kg\u003c\/p\u003e","brand":"SECO Warwick","offers":[{"title":"Default Title","offer_id":45666694234310,"sku":"4866","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0729\/7718\/7014\/files\/ENDOTHERMIC-ATMOSPHERE-GENERATOR-Type-G-60-ET-1280x1707.jpg?v=1774983168","url":"https:\/\/gvtinc.com\/products\/endothermic-atmosphere-generator","provider":"GVT, Inc.","version":"1.0","type":"link"}