{"product_id":"the-vacuum-furnace-type-200x1000","title":"The vacuum furnace TYPE 200X1000","description":"\u003cp data-start=\"25\" data-end=\"493\"\u003e\u003cstrong data-start=\"25\" data-end=\"41\"\u003eDescription:\u003c\/strong\u003e\u003cbr data-start=\"41\" data-end=\"44\"\u003eSECO\/WARWICK vacuum furnace, Type 200X1000. Vacuum furnace designed for heat treatment and heat-chemical treatment under laboratory conditions. Intended for operation in vacuum up to 10⁻⁴ mbar and recommended for low-pressure carburizing (LPC, without quenching function) and copper brazing. Cooling chamber installation is available upon client request. Technical assessment, modifications, relocation, and installation within the EU are available.\u003c\/p\u003e\n\u003cp data-start=\"495\" data-end=\"855\"\u003e\u003cstrong data-start=\"495\" data-end=\"525\"\u003eKey Components \u0026amp; Features:\u003c\/strong\u003e\u003cbr data-start=\"525\" data-end=\"528\"\u003eVacuum furnace for heat treatment and heat-chemical treatment.\u003cbr data-start=\"590\" data-end=\"593\"\u003eRecommended for low-pressure carburizing (without quenching function).\u003cbr data-start=\"663\" data-end=\"666\"\u003eRecommended for copper brazing.\u003cbr data-start=\"697\" data-end=\"700\"\u003eCooling chamber installation available upon request.\u003cbr data-start=\"752\" data-end=\"755\"\u003eHydraulic door closure.\u003cbr data-start=\"778\" data-end=\"781\"\u003eSix heating zones.\u003cbr data-start=\"799\" data-end=\"802\"\u003eHeating elements arranged above and below the load.\u003c\/p\u003e\n\u003cp data-start=\"857\" data-end=\"932\"\u003e\u003cstrong data-start=\"857\" data-end=\"874\"\u003eManufacturer:\u003c\/strong\u003e SECO\/WARWICK\u003cbr data-start=\"887\" data-end=\"890\"\u003e\u003cstrong data-start=\"890\" data-end=\"904\"\u003eModel No.:\u003c\/strong\u003e 200X1000\u003cbr data-start=\"913\" data-end=\"916\"\u003e\u003cstrong data-start=\"916\" data-end=\"925\"\u003eYear:\u003c\/strong\u003e 2017\u003cbr\u003e\u003cstrong data-start=\"910\" data-end=\"919\"\u003eLocation:\u003c\/strong\u003e Poland - SECO\/WARWICK Headquarters\u003cbr\u003e\u003c\/p\u003e\n\u003cp data-start=\"934\" data-end=\"999\"\u003e\u003cstrong data-start=\"934\" data-end=\"956\"\u003eCapacity \/ Output:\u003c\/strong\u003e\u003cbr data-start=\"956\" data-end=\"959\"\u003eUsable heating zone: Ø200 mm × 1000 mm\u003c\/p\u003e\n\u003cp data-start=\"1001\" data-end=\"1113\"\u003e\u003cstrong data-start=\"1001\" data-end=\"1025\"\u003eMaximum Temperature:\u003c\/strong\u003e\u003cbr data-start=\"1025\" data-end=\"1028\"\u003e1200°C with Type S control thermocouples\u003cbr data-start=\"1068\" data-end=\"1071\"\u003e1120°C with Type N control thermocouples\u003c\/p\u003e\n\u003cp data-start=\"1115\" data-end=\"1364\"\u003e\u003cstrong data-start=\"1115\" data-end=\"1133\"\u003eVacuum System:\u003c\/strong\u003e\u003cbr data-start=\"1133\" data-end=\"1136\"\u003eVacuum level: 10⁻⁴ mbar\u003cbr data-start=\"1159\" data-end=\"1162\"\u003eInfiltration: \u0026lt; 3 × 10⁻³ mbar × l\/s\u003cbr data-start=\"1197\" data-end=\"1200\"\u003eMaximum operating pressure: 50 mbar\u003cbr data-start=\"1235\" data-end=\"1238\"\u003eTRIVAC D40B mechanical pump – Oerlikon Leybold\u003cbr data-start=\"1284\" data-end=\"1287\"\u003eRoots WS 501 pump – Oerlikon Leybold\u003cbr data-start=\"1323\" data-end=\"1326\"\u003eRoots WS 251 pump – Oerlikon Leybold\u003c\/p\u003e\n\u003cp data-start=\"1366\" data-end=\"1621\"\u003e\u003cstrong data-start=\"1366\" data-end=\"1383\"\u003eConstruction:\u003c\/strong\u003e\u003cbr data-start=\"1383\" data-end=\"1386\"\u003eHousing material: Carbon steel\u003cbr data-start=\"1416\" data-end=\"1419\"\u003eHousing volume: 0.75 m³\u003cbr data-start=\"1442\" data-end=\"1445\"\u003eHeating chamber housing material: Carbon steel\u003cbr data-start=\"1491\" data-end=\"1494\"\u003eInsulation material: 50 mm graphite plate\u003cbr data-start=\"1535\" data-end=\"1538\"\u003eHeating element material: Graphite 1501G \/ Premium\u003cbr data-start=\"1588\" data-end=\"1591\"\u003eHeating element power: 54 kW\u003c\/p\u003e\n\u003cp data-start=\"1623\" data-end=\"1726\"\u003e\u003cstrong data-start=\"1623\" data-end=\"1636\"\u003eControls:\u003c\/strong\u003e\u003cbr data-start=\"1636\" data-end=\"1639\"\u003eProgrammable temperature controller based on PLC\u003cbr data-start=\"1687\" data-end=\"1690\"\u003eSafety controller: Eurotherm 3216i\u003c\/p\u003e\n\u003cp data-start=\"1728\" data-end=\"1907\"\u003e\u003cstrong data-start=\"1728\" data-end=\"1748\"\u003eInstrumentation:\u003c\/strong\u003e\u003cbr data-start=\"1748\" data-end=\"1751\"\u003eControl and protective thermocouple: Type N\u003cbr data-start=\"1794\" data-end=\"1797\"\u003eVacuum gauges:\u003cbr data-start=\"1811\" data-end=\"1814\"\u003eTTR 91S – Oerlikon Leybold\u003cbr data-start=\"1840\" data-end=\"1843\"\u003eCTR 100 10 Torr – Oerlikon Leybold\u003cbr data-start=\"1877\" data-end=\"1880\"\u003ePTR 90 – Oerlikon Leybold\u003c\/p\u003e\n\u003cp data-start=\"1909\" data-end=\"1987\"\u003e\u003cstrong data-start=\"1909\" data-end=\"1925\"\u003ePerformance:\u003c\/strong\u003e\u003cbr data-start=\"1925\" data-end=\"1928\"\u003eTemperature uniformity in vacuum from 750 to 1200°C: ±2°C\u003c\/p\u003e\n\u003cp data-start=\"1989\" data-end=\"2012\"\u003e\u003cstrong data-start=\"1989\" data-end=\"2000\"\u003eWeight:\u003c\/strong\u003e\u003cbr data-start=\"2000\" data-end=\"2003\"\u003e3000 kg\u003c\/p\u003e","brand":"SECO Warwick","offers":[{"title":"Default Title","offer_id":45666708586694,"sku":"4867","price":68107.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0729\/7718\/7014\/files\/The-vacuum-furnace-TYPE-200X1000-1280x850.jpg?v=1774983371","url":"https:\/\/gvtinc.com\/products\/the-vacuum-furnace-type-200x1000","provider":"GVT, Inc.","version":"1.0","type":"link"}